Skip to main content

Technical Talk by Dr. Anoop Sattineni (Auburn University)

Speaker
Dr. Anoop Sattineni, William A. Hunt Associate Professor
Venue
Room A01-018, Saraswathi Block, Sahyadri Campus
From - To
-
Event Category
Talk

Dr. Anoop Sattineni, William A. Hunt Associate Professor,  McWhorter School of Building Science at Auburn University, will be visiting IIT Palakkad on 27th November 2026 (Friday) and will be delivering a technical talk on "Wearable Sensing Devices for Construction Health & Safety"

Abstract: Wearable sensing devices (WSDs) monitor a construction worker's physiological state and surroundings for safety and health, but only while worn, so their benefit depends on acceptance and continued use. Prior studies have developed implementation frameworks from one-time surveys of construction personnel. However, how field workers accept and keep using WSDs on their own jobsites remains underexplored. Without this evidence, contractors have little basis for deciding on (a) data and alerts, (b) on-body placement, (c) training and (d) device class. The main goal of this dissertation is to develop a decision framework to support general contractors and subcontractors in the implementation of WSDs for construction worker safety and health. To achieve this goal, a multiphase mixed-methods design of six studies was employed. Of 17 interviewed field workers without workplace WSD use, 13 considered alerts useful for heat and 10 for moving equipment. Fifteen would use a company-provided device, but for collecting physiological and location data, 15 and 16 answered "depends." When 17 field workers wore four powered-off devices, one per workday, 16 wore the wristband six to eight hours, and all 15 who ranked on-body placements put the wrist first. Of 15 workers provided with a commercially available wrist-worn device, 9 of the 11 interviewed at nine months had a working device. In an experimental pilot, a lower-cost wrist-worn device read heart rate 7.0 beats per minute below an occupational heat-stress wearable on average across nine volunteers (13.2 in simulated work). Apart from the published alert findings, these results are preliminary, from small samples mostly on one U.S. general contractor's projects. For the 17 interviewed, the barrier appeared to be the rules for physiological and location data, not willingness to use a device. The framework will be developed from these findings and validated through a nonprobability survey of field-based construction professionals.